General
Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering.
The meter could measure6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.have the functions of telemetering,teleindication,teleadjusting, metering at real time,energy quality abnormal alarm, data storage and processing, data interaction.
Functions
| |
|
Technical Parameters
Technical parameter Index Input DC rated voltage 1 channel: -48VDC DC current 6 channels hall sensors: total 200A/5V, China Telecom, China Commercial power 1 channel: 0-5VDC Overload capacity Voltage:1.2times continued,2 times continued 1s; Accuracy (superposition hall sensors) 1%In≤I≤10%In error±2.5%; I>10%In error±2% Measurement resolution Voltage output accuracy 0.01V; current output accuracy 0.01A; Functions Basic function Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED indicator display;485 communication. Metering function Start current: under rated voltage, when the load current value of the meter doesn’t exceed 1% of the max. current, the meter starts. Alarm function DC voltage output low alarm,DC voltage output high alarm,one Timing function support broadcast timing, could remote timing to the meter Communication Single channel RS485, baudrate 9600bps, can be set to 1200BPS, Hall sensor power supply Power supply output:+12V/100Ma, -12V/50mA Clock accuracy ≤0.5S/d(23℃), ≤1S/d(-20℃-60℃), Auxiliary Voltage range -40V~-60VDC Power consumption Whole device≤2W( no hall power supply output) Storage It has the storage function of historical power data and historical alarm information, and the memory is 2MB Insulation resistance ≥40MΩ Environment Temperature Working : -20℃~+60℃; storage:-40℃~+70℃ Humidity ≤98% no condensation, no corrosive gas place Altitude ≤4000m Protection level IP20 Material flame retardent Terminal glow wire temperature 960℃±10℃ ,shell glow wire Installation Standard 35mm din rail Lightning Voltage input Peak value 5kA Auxiliary supply Peak value 5kA
Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd
channel reserve 100A/5V
monitoring
Current: 1.2 times continued,10 times continued 1s
power output accuracy 0.01kw; energy output accuracy 0.01kwh
Shunt running current: when there is no current in the current
circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change.
power down alarm, module voltage loss alarm, metering branch
error alarm, internal program error alarm, clock error alarm,
memory failure alarm, AC input power failure alarm
through RS485 communication.
2400bps, 4800bps.
Communication protocol: standard or custmized
supply
temperature 6500℃±15℃
protection
(differential mode)
(differential mode)
Wiring
① Digital input ② Brand/Model ③ Panel ④ Digital output ⑤ Pluse output |
Dimension
Network
FAQ
Q:The measurement of the metering module is inaccurate.
A:Check input whether the polarity and direction of the input voltage and current wiring are correct;Whether the direction of the primary current of the Hall sensor is correct; Whether the output signal of the Hall sensor matches the input signal required by the module; Check whether the output negative pole of the voltage output Hall sensor is connected to the module GND.
Q:Communication is abnormal.
A:Check communication whether the communication cable is normal; check whether the communication terminals A and B are staggered; check whether the address of the module is set correctly and whether the communication baud rate is set correctly; if the communication of multiple modules is not normal, first try whether the single-machine communication is normal.
Q:The metering module cannot bedisplayed normally.
A:Check whether it is caused by insufficient load capacity due to the built-in power supply to the hall sensor. Change the external switching power supply to power the hall.
Package
MINIMUM PACKAGE | ||||
MINIMUM PAKAGE | Package dimensions(1 PC) 170*150*130mm | Pakage Weight(1 PC) 0.31Kg | ||
WHOLE BOX PAKAGE | Package dimensions(36 PCS) 535*525*475mm | Pakage Weight(36 PCS) 11.16kG | ||
PRODUCT HS CODE | 9028309000 |
ATTENTION ! The above packing and weight data are only refer to model AMC16-DETT. For other models or optional functions, please contact the salesman for details, thank you for your cooperation! |